Abbott Reagent i-STAT Chem8+ Cartridge

Abbott

Abbott Reagent i-STAT Chem8+ Cartridge

SKU: 550531
MFG Part #: 09P31-26
  • The i-STAT CHEM8+ cartridge with the i-STAT 1 System is intended for use in arterial or venous whole blood in point of care or clinical laboratory settings
  • Each i-STAT single-use cartridge uses advanced biosensor technology that applies microfluidics to process the most comprehensive range of clinical tests in a single platform
  • To perform a test, 2 to 3 drops of blood are applied to a cartridge, which is then inserted into the i-STAT handheld
  • Prior to running a test, each cartridge initiates a series of preset quality control diagnostics, from monitoring the quality of the sample to validating the reagent
  • Each test cartridge contains chemically sensitive biosensors on a silicon chip that are configured to perform specific tests
    True Know-How
    Ask our experts
    In Stock
    Usually ships in 1 - 3 Days
    This product is non-returnable

    Price:
    $359.00 25 / Box

    Description

    The CHEM8+ CARTRIDGE is a single-use, in vitro diagnostic test that combines a battery of basic metabolic tests including sodium, potassium, chloride, ionized calcium, total CO(2), glucose, blood urea nitrogen (BUN) and creatinine.

    Features

    • The i-STAT CHEM8+ cartridge with the i-STAT 1 System is intended for use in arterial or venous whole blood in point of care or clinical laboratory settings
    • Each i-STAT single-use cartridge uses advanced biosensor technology that applies microfluidics to process the most comprehensive range of clinical tests in a single platform, allowing clinicians to access the time-sensitive diagnostic information they need
    • To perform a test, 2 to 3 drops of blood are applied to a cartridge, which is then inserted into the i-STAT handheld
    • Prior to running a test, each cartridge initiates a series of preset quality control diagnostics, from monitoring the quality of the sample to validating the reagent
    • Each test cartridge contains chemically sensitive biosensors on a silicon chip that are configured to perform specific tests

    Product Specifications and Resources

    Application Reagent
    CLIA Classification CLIA Moderate Complexity
    For Use With For use with i-STAT1 System
    Form Cartridge
    Number of Tests 9 Tests
    Sample Type Whole Blood Sample
    Storage Requirements Requires Refrigeration
    Test Name Sodium / Potassium / Chloride / Ionized Calcium / Urea Nitrogen / Glucose / Creatinine / Hematocrit / TCO2
    Test Type Renal / General Chemistry
    Time to Results 2 Minute Results
    Volume 25 Cartridges
    UNSPSC Code 41115808
    What's in the Box
  • (25) i-STAT CHEM8+ cartridge